Eclipse 4000 Maintenance Manual
01/12/02 V2.00 Page 4
INSTALLATION:
1. Once located into the correct position, the system must be locked down to prevent movement and
contact with adjacent line machinery. It should also be level in operation.
2. Always use an RCD feed for the system (16 Amp rating).
3. Ensure that terminal covers are replaced after connection of the mains power cable.
4. Release the Checkweigher motor cables and connect to the motors and secure. Ensure the sealing
rubber is located in place prior to securing.
5. Connect a suitable air supply (4 to 6 BAR) to the system. MAXIMUM MUST NOT EXCEED 10
BAR.
6. Check that none of the conveyors are obstructed or in contact with adjacent equipment.
7. The customers should fit guarding at the interface of the CINTEX system with their own system.
There is a potential hazard at the conveyor junctions plus the reject device on the outfeed
conveyor.
8. If the system is used as a stand alone system, then extra guarding around the outfeed end and reject
device should be fitted.
NOTE: When the conveyors are stopped the reject devise is disabled.
It is advisable to isolate the system before undertaking any maintenance or cleaning
work.
Combined System:
Isolator Switch E-Stop
CS4000 electronics Cabinet Start Button
Mains In
Metal Detector Head CW Reject Hood
MD Reject Bin